60/70/80/90 SERIES
FAN CONTACTORS
|
- Measurements on 70 series locomotives indicates that the original OEM fan contactors are marginally rated for the operation encountered:
- FCF-B steady state current exceeds contactor rating by approximately 15 percent
- FCF-B starting surge current exceeds contactor rating by approximately 67 percent
- FCS steady state current exceeds rating by approximately 10 percent
Cooling Fan/Blower Contactor Ratings
Original Installation Versus RSA Upgrade
Existing OEM Contactor
NEMA Size 3
AC-3 Rating - 90 amps
Surge Rating - 800 amps
RSA Contactor
NEMA Size 4
AC-3 Rating - 180 amps
Surge Rating - 1800 amps
|
 |
70 SERIES FAN CONTACTORS |
|
|
|